Rated supply voltage | 100 to 240 VAC 50/60 Hz |
---|---|
Operating voltage range | 85% to 110% of rated supply voltage |
External power supply | 80 mA, 12 VDC ±10% (5% ripple max.) |
Power consumption | 10VA (at 240 VAC) |
Time ranges(Number of ranges) | 8 |
Time ranges | 0.01 s to 99.99 s / 0.1 s to 999.9 s / 1 s to 9999 s / 0.1 min to 999.9 min / 0.1 h to 999.9 h / 1 h to 9999 h 1sec~99min59sec |
Select method | Rotary DIP switch |
Input signals | Reset, Gate |
Minimum input signal width | 20 ms(Reset, Gate) |
Output modes | N F C R K P Q |
Control output (Contact output) | Type: SPDT Switching capacities (Resistive load): 3 A at 250 VAC/3 A at 24 VDC Minimum applicable load: 10 mA at 5 VDC (failure level: P Reference value) |
Control output (Solid state output) | Transistor output (NPN open collector) Switching capacities: 100 mA max. 30 VDC max. |
One-shot output time | 0.1 to 1 s (variable) |
Reset system | Power reset / External reset / Manual reset / Automatic reset |
Power reset | Minimum power-opening time: 0.5 s |
Timer mode | Elapsed time (UP) and remaining time (DOWN) (selectable) |
Display method | 7-segment LED |
Digit | 4 digit |
Character height | 10 mm (Red) |
Ambient temperature | Operating: -10 to 55 ℃ Storag: -25 to 65 ℃ |
Ambient humidity | Operating: 35 to 85%RH |
Total accuracy | Accuracy of operating time setting error temperature influences and voltage influences (including the rise time of the power source and the operating times of the internal and output circuits). Power-ON start: ±0.01% ±50 ms max. The values are based on the set value. Accuracy of operating time setting error temperature influences and voltage influences (including the rise time of the power source and the operating times of the internal and output circuits). Reset start: ±0.005% ±30 ms max. The values are based on the set value. |
Insulation resistance | 100 MΩ min. (at 500 VDC) Between current carrying terminals and exposed non-current carrying metal parts / Between non-continuous contacts |
Dielectric strength | Between current carrying terminals and exposed non-current carrying metal parts: 2000 Between non-continuous contacts: 750 |
Impulse withstand voltage | Between operating power supply terminals: 6 kV Between current carrying terminals and exposed non-current carrying metal parts: 6 kV |
Noise immunity | Between operating power supply terminals: ±2 kV Between input terminals: ±500 V Square-wave noise by noise simulator |
Static immunity | Mulfunction: 8 kV |
Vibration resistance (Destruction) | 10 to 55 Hz, 0.375-mm single amplitude each in 3 directions for 2 h |
Vibration resistance (Malfunction) | 10 to 55 Hz, 0.25-mm single amplitude each in 3 directions for 10 min |
Shock resistance (Destruction) | 300 m/s**2, 3 times each in 6 directions |
Shock resistance (Malfunction) | 100 m/s**2, 4 times each in 6 directions |
Mechanical life | 10,000,000 operations min. |
Electrical life | 100,000 operations min. (3 A at 250 VAC resistive load) |
Mounting method | Flush mounting |
External connection method | Screw terminal |
Case color | Light gray (Munsell 5Y7/1) |
Attachment | Mounting bracket |
Accessory (sold separately) | Y92H-5: Mounting bracket |
Weight | 約360g |