H7AN-R6DM AC100-240

buiding

Type: H7AN-R6DM AC100-240

Function 1 Stage Preset Counter
Preset stages 1stages
Rated supply voltage 100 to 240 VAC 50/60 Hz
Operating voltage range 85% to 110% of the rated power supply voltage
Power consumption Approx. 10 VA (at 100 VAC)
External power supply 12 VDC ±10% 80 mA (permissible ripple: 5%(p-p) Max.)
Counter (Count range) 0~999999
Counter (Max. counting speed) 30 Hz/5 kHz (switching) (Minimum counting input signal width: 16.7 ms (ON/OFF ratio: 1:1)/0.1 ms (ON/OFF ratio: 1:1))
Counter (Input mode) Increment decrement or increment/decrement (switchable)
Counter (Output modes) N / F / C / R / K / P / Q
Counter One-shot time) 0.1 to 1 s variable
Counter (Reset system) External, manual, automatic and power reset (when set the SW3 for No memory backup)
Input signal CP1 / CP2 / Reset
Input method Voltage input
No-voltage input (Contact input) Use a contact which can adequately switch 2.5 mA at 12 V.
Voltage input Hight level: 5 to 30 VDC
Low level: 0 to 2 VDC
Input resistance: 4.7 kΩ
Minimum input signal width External reset: 20 ms
Manual reset: 20 ms
Automatic reset: 100 to 1000 ms (C, R, P and Q mode)
Control output (Contact output) SPDT
Switching capacity: 3 A at 250 VAC/30 VDC, resistive load (cos phi=1)
Minimum applicable load: 10 mA at 5 VDC (failure level:P reference value)
Control output (Solid-state output) Output type: Transistor output (NPN open collector)
Output resistance: 1.5 kΩ
Switching capacity: 30 VDC max., 100 mA max.
Display method 7-segment LED
Digits 6digits
Character height Count value: 8 mm (Red)
Zero suppression: Not provided
Prescaling function Not provided
Key protection Not provided
Teaching function Not provided
Batch counting function Not provided
Communications Not provided
Memory backup Non-volatile memory (Number of rewite: 1,000,000 operations min.)
Surrounding air temperature Operating: -10 to 55 ℃
Storage: -25 to 65 ℃
Ambient humidity Operating: 35 to 85%
Storage: 35 to 85%
Insulation resistance 100 MΩ min. (at 500 VDC)
Between current carrying terminals and exposed non-current carrying metal parts / Between non-continuous contacts
Dielectric withstand voltage Between current carrying terminals and exposed non-current carrying metal parts:2000 VAC 50/60 Hz for 1 min
Between non-continuous contacts:750 VAC 50/60 Hz for 1 min
Impulse withstand voltage Between power terminals:6.0 kV
Between current carrying terminals and exposed non-current carrying metal parts:6.0 kV
Noise immunity Between power terminals:±2k V
Between input terminals:±500 V
Square-wave noise by noise simulator (Pulse width: 100 ns/1 µs, 1-ns rise)
Static immunity ±8 kV (malfunction), ±15 kV (destruction)
Vibration resistance (Destruction) 10 to 55 Hz, 0.375-mm single amplitude each in 3 directions for 2 h
Vibration resistance (Malfunction) 10 to 55 Hz, 0.25-mm single amplitude each in 3 directions for 10 min
Shock resistance (Destruction) 300 m/s**2, 3 times each in 6 directions (3 axes)
Shock resistance (Malfunction) 100 m/s**2, 2 times each in 6 directions
Mechanical life expectancy 10,000,000 operations min.
Electrical life expectancy 100,000 operations min. (3 A at 250 VAC, resistive load)
Degree of protection Case front: JEM IP30
Mounting method Flush mounting
External connection method Screw terminal
Case color Light gray (Munsell 5Y7/1)
Accessories Mounting bracket
Weight Approx. 360 g