type | Square type unshielded type |
---|---|
Detection distance | 10 mm ± 10% |
Set distance | 0 to 8 mm |
Hysteretic | 15% or less of the detection distance |
Detectable object | Magnetic metal (Detection distance of nonmagnetic metal decreases) |
Standard detection object | Iron 40 × 40 × 1 mm |
Response frequency | 10 Hz (average value) |
Type of power supply | AC 2 wire type |
Power-supply voltage | AC 100 to 220 V |
Operating voltage range | AC 90 ~ 250V |
Control output (switching capacity) | 10 to 200 mA |
Indicator light | Operation indicator light (red) |
action mode | No |
Protection circuit | Surge absorption |
Ambient temperature range | At use: -25 to 70 ° C Storage: -25 to 70 ° C (with no freezing) |
Ambient humidity range | When used: 35 to 95% RH Storage: 35 to 95% RH (with no condensation) |
Influence of temperature | Change in detection distance within the temperature range of -25 to + 70 ° C is within ± 10% (based on the detection distance at 23 ° C) |
Effect of voltage | Within the range of the rated voltage ± 10%, the change in the detection distance is within ± 1% (based on the detection distance at the rated power supply voltage) |
Insulation resistance | Between charging unit and casing: 50 MΩ or more (DC 500 V mega) |
Withstand voltage | Between charging unit and casing: AC 2000 V 50/60 Hz 1 min |
Vibration (durability) | 10 to 55 Hz Double amplitude 1.5 mm X, Y, Z direction 2 h |
Impact (durability) | 500 m / s ** 2 X, Y, Z 10 times in each direction |
Protective structure | IEC standard: IP 67 Internal standard: oil resistant |
Connection method | Code pullout type (Cord length: 5 m) |
Material | Case: Heat resistant ABS detection surface: Heat resistant ABS |
accessories | instruction manual |