Item | Specifications |
---|---|
Product Number | NA40-4 |
Part Number | NA40-4 |
Sensing height | 120 mm 4.724 in |
Sensing range | 5 m 16.404 ft |
Beam pitch | 40 mm 1.575 in |
Sensing object | dia. 60 mm dia. 2.362 in or more opaque object (Completely beam interrupted object) |
Supply voltage | 12 to 24 V DC plus or minus 10 % Ripple P-P 10 % or less |
Current consumption | Emitter: 30 mA or less Receiver: 60 mA or less |
Sensing output | NPN open-collector transistor - Maximum sink current: 100 mA - Applied voltage: 30 V DC or less (between sensing output and 0 V) - Residual voltage: 1.6 V or less (at 100 mA sink current) |
Sensing output:Output operation | ON when all beam channels are received / OFF when one or more beam channels are interrupted |
Self-diagnosis output | NPN open-collector transistor - Maximum sink current: 50 mA - Applied voltage: 30 V DC or less (between self-diagnosis output and 0 V) - Residual voltage: 1.6 V or less (at 50 mA sink current) |
Self-diagnosis output:Output operation | OFF when unstable light received condition continues for 5 sec. or more, or the output transistor fails |
Response time | 12 ms or less |
Interference prevention function | Incorporated (Two units of sensors can be mounted close together.) |
Protection | IP65 (IEC) |
Ambient temperature | -10 to +50 degrees +14 to +122 degrees Fahrenheit (No dew condensation or icing allowed), Storage: -10 to +60 degrees +14 to +140 degrees Fahrenheit |
Emitting element | Infrared LED (synchronized scanning system) |
Material | Protection enclosure: Aluminum Unit case: ABS Front cover: Acrylic Lens: Acrylic |
Weight(Total weight of emitter and receiver) | 400 g approx. |
Dummy | MS-NA40-1 (Sensor mounting bracket): 1 set for emitter and receiver Adjusting screwdriver: 1 pc. |