FX-501 | Digital Fiber Sensor FX-500 Ver.2

 

buiding
 

Spec Detail

Item Specifications
Product Number FX-501
Part Number FX-501
CE marking directive compliance EMC Directive, RoHS Directive
Supply voltage 12 to 24 V DC+10-15 % Ripple P-P 10 % or less
Power consumption Normal operation: 960 mW or less (current consumption 40 mA or less at 24 V supply voltage)
ECO mode: 680 mW or less (current consumption 28 mA or less at 24 V supply voltage)
Output NPN open-collector transistor
- Maximum sink current: 100 mA (Note 1)
- Applied voltage: 30 V DC or less (between output and 0 V)
- Residual voltage: 2 V or less (Note 2) (at maximum sink current)
(Note 1) 50 mA max. if 5 or more standard types are connected together.
(Note 2) 50 mA max. if 5 or more standard types are connected together. (25 mA in case of 2-output type and cable type)
Output:Output points 1 point
Output:Output operation Switchable either Light-ON or Dark-ON by L/D mode
Output:Short-circuit protection Incorporated
Response time H-SP: 25 micro s or less
FAST: 60 micro s or less
STD: 250 micro s or less
LONG: 2 ms or less
U-LG: 4 ms or less
HYPR: 24 ms or less, selectable
External input -
External input(switchable with Output 2) -
Possible external input function -
Sensitivity setting 2-point teaching / Limit teaching / Full-auto teaching / Manual adjustment
Incident light intensity display range H-SP / FAST / STD: 0 to 4,000
LONG: 0 to 8,000
U-LG / HYPR: 0 to 9,999
Timer function Incorporated with variable OFF-delay / ON-delay /One-shot / ON-delay - OFF-delay / ON-delay - One-shot timer, switchable either effective or ineffective
Timer function:Timer period Timer range ''ms'': 0.5 ms approx., 1 to 9,999 ms approx., 1 ms approx.
Timer range ''sec.'': 0.5 s approx., 1 to 32 s approx., 1 s approx.
Timer range ''1/10 ms'': 0.05 ms approx., 0.1 to 999.9 ms approx., 0.1 ms approx.
each output is set individually
Emission amount setting function Incorporated, 3 levels (each level 25 to 100 %) + Auto setting [1 level (25 to 100 %) when using H-SP mode]
Interference prevention function Incorporated (Note) , selectable either automatic interference prevention or different frequency
(Note) Number of sensor heads which is possible to be mounted closely in auto interference prevention function depends on response time as shown in table below.Number of sensor heads which is possible to be mounted closely in different frequency Interference prevention function is up to 3 units.
- Number of sensor heads mountable closely (Unit: set)
Response time: IP-1
H-SP: 0
FAST: 2
STD: 4
LONG: 8
U-LG: 8
HYPR: 12
Various settings Hysteresis setting / Shift amount setting / Emission power setting / Display turning setting / ECO setting / Data bank loading saving setting / Copying setting / Code setting / Reset setting / Logical calculation setting / Threshold value tracking setting, etc.
Protection IP40 (IEC)
Ambient temperature -10 to +55 ℉ +14 to +131 ℉ [If 4 to 7 units are mounted in cascade: -10 to +50 ℉ +14 to +122 ℉ or if 8 to 16 units are mounted in cascade: -10 to +45 ℉ +14 to +113 ℉ ] (No dew condensation or icing allowed), Storage: -20 to +70 ℉ -4 to +158 ℉ 
Emitting element (modulated) Red LED (Peak emission wavelength: 643 nm 0.025 mil)
Material Enclosure, Case cover: Polycarbonate
Switch: Polyacetal
Cable -
Cable extension -
Weight Net weight: 15 g approx.
Gross weight: 70 g approx.
Accessory FX-MB1 (Amplifier protection seal): 1 set