Panasonic GD-C1 | Metal-sheet Double-feed Detector GD

buiding
 

Spec Detail

Item Specifications
Product Number GD-C1
Part Number GD-C1
Type Standard
Supply voltage 12 to 24 V DC plus or minus 10 % Ripple P-P 10 % or less
Current consumption 12 V DC: 700 mA or less, 24 V DC: 400 mA or less
Outputs (OUT-1 , OUT-2 , ALM. , Answer-back ) NPN open-collector transistor
-Maximum sink current: 100 mA
-Applied voltage: 30 V DC or less (between output and 0 V)
-Residual voltage: 1 V or less (at 100 mA sink current), 0.4 V or less (at 16 mA sink current)
Outputs (OUT-1 , OUT-2 , ALM. ,Answer-back ) : Output Operation : OUT-1 OFF above the one-sheet threshold level
Outputs (OUT-1 , OUT-2 , ALM. ,Answer-back ) : Output Operation : OUT-2 OFF above the two-sheet threshold level
Outputs (OUT-1 , OUT-2 , ALM. ,Answer-back ) : Output Operation : ALM. OFF when an error occurs
Outputs (OUT-1 , OUT-2 , ALM. ,Answer-back ) : Short-circuit protection Incorporated
Response time Automatically selected either 5 ms or less, or 30 ms or less, depending on the object
Set level storage function Set values of eight channels stored
Set level teaching function Incorporated
External setting function Incorporated
Indicators : Power Green LED (lights up when the power is ON)
Indicators : Self-diagnosis (ALM.) Red LED (lights up during SET mode and when an error occurs during RUN mode)
Indicators : Sensing mode (SENSE) 2-color indicator (lights up green during normal sensing mode, but yellow during precise sensing mode)
Indicators : OUT-1 Green LED (lights up when OUT-1 is OFF, and blinks twice on completion of 0-ADJ. or SET-1 setting in SET mode)
Indicators : OUT-2 Red LED (lights up when OUT-2 is OFF, and blinks twice on completion of 0-ADJ. or SET-2 setting in SET mode)
Indicators : Sensing level Yellow LED x 1 and green LED x 6 (indicate the sensing level)
Timer function Approx. 50 ms fixed delay timer (switchable either effective or ineffective)
Ambient temperature -10 to +50 ℃ +14 to +122 ℉ (No dew condensation or icing allowed), Storage: -25 to +70 C° -13 to +158 ℉
Ambient humidity 45 to 85 % RH, Storage: 35 to 90 % RH
Voltage withstandability 1,000 V AC for one min. between all supply terminals connected together and enclosure
Insulation resistance 50 MOhm , or more, with 250 V DC megger between all supply terminals connected together and enclosure
Vibration resistance 10 to 55 Hz frequency, 0.75 mm 0.030 in double amplitude in X, Y and Z directions for two hours each
Shock resistance 300 m/s2 acceleration (30 G approx.) in X, Y and Z directions three times each
Material Heat-resistant ABS
Weight Net weight: 440 g approx.
Accessory Insulation plate: 2 pcs.