Item | Specifications |
---|---|
Product Number | EX-L221 |
Part Number | EX-L221 |
CE marking directive compliance | EMC Directive, RoHS Directive |
Sensing range | 45 to 300 mm 1.772 to 11.811 in (Note)The sensing range is specified for white non-glossy papar (100 x 100 mm 3.937 x 3.937 in) as the object. |
Emission spot size (Typical) | ø1 mm ø0.039 in or less (at a sensing distance of 300 mm) |
Sensing object | ø1 mm ø0.039 in or less (at a sensing distance of 300 mm) |
Minimum sensing object (Typical) | Gold wire of ø0.01 mm ø0.0004 in (Note)Typical values when the sensitivity adjuster is optimally adjusted. |
Hysteresis | 20 % or less of operation distance |
Repeatability | Perpendicular to sensing axis: 0.05 mm 0.0020 in or less |
Repeatability (Typical)(perpendicular to sensing axis) | 0.02 mm 0.0008 in or less (at 100 to 200 mm sensing distance) (Note)Typical values when the sensitivity adjuster is optimally adjusted. |
Supply voltage | 12 to 24 V DC plus or minus 10 % Ripple P-P 10 % or less |
Current consumption | 15 mA or less |
Output | NPN open-collector transistor - Maximum sink current: 50 mA - Applied voltage: 26.4 V DC or less (between output and 0 V) - Residual voltage: 2 V or less (at 50 mA sink current), 1 V or less (at 16 mA sink current) |
Output:Output operation | Light-ON / Dark-ON selectable by the output operation switching input |
Output:Short-circuit protection | Incorporated (short-circuit protection / inverse polarity protection) |
Response time | 0.5 ms or less |
Automatic Interference prevention function | Incorporated (Two sensors can be mounted close together.) |
Sensitivity adjuster | Continuously variable adjuster |
Protection | IP67 (IEC) |
Ambient temperature | -10 to +55 ℃ +14 to +131 ℉ (No dew condensation or no icing condition), Storage: -30 to +70 ℃ -22 to +158 ℉ |
Ambient humidity | 35 to 85 % RH, Storage: 35 to 85 % RH |
Ambient illuminance | Incandescent light: 3,000 lx or less at the light-receiving face |
Voltage withstandability | 1,000 V AC for one min. between all supply terminals connected together and enclosure |
Insulation resistance | 20 MOhm , or more, with 250 V DC megger between all supply terminals connected together and enclosure |
Vibration resistance | 10 to 500 Hz frequency, 1.5 mm 0.059 in double amplitude (10 G max.) in X, Y and Z directions for two hours each |
Shock resistance | 500 m/s2 acceleration (50 G approx.) in X, Y and Z directions three times each |
Emitting element | Red semiconductor laser Class 1 (IEC / JIS/ FDA) (Note:This product complies with 21 CFR 1040.10 and 1040.11 Laser Notice No. 50, dated June 24, 2007, issued by CDRH (Center for Devices and Radiological Health) under the FDA (Food and Drug Administration) (Maximum output: 390 μW, Peak emission wavelength: 655 nm 0.026 mil) |
Material | Enclosure: Polybutylene terephthalate, Front cover: Acylic, Lens: Glass, Indicator part: Polyarylate |
Cable | 0.15 mm2 4-core (emitter of a thru-beam type: 2-core) cabtyre cable, 2 m 6.562 ftlong |
Cable extension | Extension up to total 50 m 164.042 ft is possible with 0.3 mm2, or more, cable. |
Weight | Net weight: 45 g approx Gross weight: 60 g approx |
Accessory | MS-EXL2-3 (Mounting plate): 1 pc. |