Item | Specifications |
---|---|
Product Number | HL-G112-S-J |
Part Number | HL-G112-S-J |
CE marking directive compliance | EMC Directive, RoHS Directive |
Type | High functionality type |
Measurement center distance | 120 mm 4.724 in |
Measuring range | ± 60 mm ± 2.362 in |
Resolution | 8 μm 0.315 mil |
Linearity | ± 0.1 % F.S. |
Temprerature characteristics | ± 0.08 % F.S. / ℃ |
Light source | Red semiconductor laser, Class 2 (IEC / JIS / FDA (Note:This product complies with 21 CFR 1040.10 and 1040.11 Laser Notice No. 50, dated June 24, 2007, issued by CDRH (Center for Devices and Radiological Health) under the FDA (Food and Drug Administration).) , Laser Notice No. 50) Max. output: 1 mW (Peak emission wavelength: 655 nm 0.026 mil) |
Beam diameter | 1.0 × 1.5 mm 0.039 x 0.059 in (Note) This beam diameter is the size at the measurement center distance. These values were defined by using 1/e2 (13.5 %) of the center light intensity. If there is a slight leakage of light outside the normal spot diameter and if the periphery surrounding the sensing point has a higher reflectivity than the sensing point itself, then the results may be affected. |
Receiving element | CMOS image sensor |
Supply voltage | 24 V DC ± 10 % including ripple 0.5 V (P-P) |
Current consumption | 100 mA or less |
Sampling rate | 200 μs, 500 μs, 1 ms, 2 ms |
Analog output : Voltage | Output range: 0 to +10.5 V (normal), 11 V (alarm) Output impedance: 100 Ohm |
Analog output : Current | Output range: 3.2 to 20.8 mA (normal), 21.6 mA (alarm) Load impedance: 300 Ω or less |
Outputs (OUT 1, OUT 2, OUT 3) | Judgment output or alarm output (Setting can be selected.) Selectable NPN transistor open-collector or PNP transistor open-collector <In case of using NPN output> -Maximum sink current: 50 mA -Applied voltage: 3 to 24 V DC (between output and 0 V) -Residual voltage: 2 V or less (at 50 mA of sink current) <In case of using PNP output> -Maximum source current: 50 mA -Residual voltage: 2.8 V or less (at 50 mA of source current) |
Output (OUT 1, OUT 2, OUT 3) : Output operation | Opened when the amount of light is insufficient. |
Output (OUT 1, OUT 2, OUT 3) : Short circuit protection | Incorporated (automatic restoration) |
Output polarity setting input | NPN open collector output operates when 0 V is connected. PNP open collector output operates when 24 V DC is connected. |
Timing input | NPN output operates when 0V is connected and NPN is set. (It depends on the setting.) PNP output operates when external power + is connected and PNP is set. (It depends on the setting.) |
Multi input | Zero set, zero set off, reset, memory switching, teaching, saving, and laser control according to the input time. In case NPN output is selected, Function varies according to the time 0 V is connected NPN. In case PNP output is selected, Function varies according to the time external power + is connected. |
Communications interface | RS-422 or RS-485 (selectable) Baud rate: 9,600/19,200/38,400/115,200/230,400/460,800/921,600 bps Data length 8 bit, Stop bit length 1 bit, Without parity check, BCC check, Termination code: CR |
Indicator : Laser emission | Green LED (lights up during laser emission) |
Indicator : Alarm | Orange LED lights up when this product cannot measure because of insuffienct or excessive light intensity. |
Indicator : Measurement range | Three yellow LED |
Digital display | Red LED 5 digit display |
Degree of pollution | 2 |
Operating altitude | 2,000 m 6561 ft or less |
Environmental resistance : Protection | IP67 |
Ambient temperature | -10 to +45 ℃ +14 to +113 ℉ (No dew condensation allowed), Storage: -20 to +60 ℃-4 to +140 ℉ |
Ambient humidity | 35 to 85 % RH, Storage: 35 to 85 % RH |
Ambient illuminance | Incandescent light: 3,000 liter x or less at the light-receiving face (Note) The fluctuation by ambient illuminance is ± 0.1 % F.S. or less. |
Insulation resistance | 20 MOhm , or more, with 250 V DC between all supply teminals connected together and enclosure |
Voltage withstandability | 1,000 V AC for one min. between all supply terminals connected together and enclosure |
Vibration resistance | 10 to 55 Hz (period: 1 min.) frequency, 1.5 mm 0.059 in double amplitude in X,Y and Z directions for two hours each |
Shock resistance | 500 m/s2 acceleration (50 G approx.) in X,Y and Z directions three times each |
Material | Enclosure: PBT Front cover: Acrylic Cable: PVC |
Cable | 14-core cabtyre cable with connector, 0.5 m 1.640 ft long |
Cable extension | Extension up to total 20 m 65.617 ft is possible with optional cable. |
Weight | Net weight: 70 g approx. (not including cable), 110 g approx. (including cable) Gross weight: 160 g approx. |
Accessory | Warning label: 1 set |
Remark | Where measurement conditions have not been specified precisely, the conditions used were as follows: supply voltage 24 V DC, ambient temperature +20 ℃ +68 ℉, sampling rate 500 μs, average number of samples: 1024, measurement center distance, object measured is made of white ceramic and analog measurement values. |