Item | Specifications |
---|---|
Product Number | NX5-M10RB |
Part Number | NX5-M10RB |
CE marking directive compliance | Low Voltage Directive, EMC Directive, RoHS Directive |
Sensing range | 10 m 32.808 ft |
Sensing object | dia. 20 mm dia. 0.787 in or more opaque object (Note) If slit masks (optional) are fitted, an object as small as 3 x 6 mm 0.118 x 0.236 in can be detected. |
Hysteresis | - |
Repeatability(perpendicular to sensing axis) | 0.1 mm 0.004 in or less |
Supply voltage | 24 to 240 V AC +10-15 % or 12 to 240 V DC +10-15 % Ripple P-P 10 % or less |
Power consumption | Emitter: 1 VA or less Receiver: 2 VA or less |
Output | Relay contact 1 c - Switching capacity: 250 V AC 1 A (resistive load), 30 V DC 2 A (resistive load) - Electrical life: 500,000 or more switching operations (switching frequency 3,600 operations/hour), 100,000 or more switching operations (switching frequency 3,600 operations/hour) - Mechanical life: 100 million or more switching operations (switching frequency 36,000 operations/hour) |
Output:Output operation | Dark-ON |
Response time | 10 ms or less |
Operation indicator | Red LED (lights up when the output is ON) |
Stability indicator | Green LED (lights up under stable light received condition or stable dark condition) |
Power indicator | - |
Sensitivity adjuster | Continuously variable adjuster |
Automatic Interference prevention function | (Use optional interference prevention filters) |
Pollution degree | 3 (Industrial environment) |
Protection | IP66 (IEC) |
Ambient temperature | -20 to +55 degrees -4 to +131 degrees Fahrenheit (No dew condensation or icing allowed) (Note) , Storage: -30 to +70 degrees -22 to +158 degrees Fahrenheit (Note) In case the sensor is to be used at an ambient temperature of -15 degrees +5 degrees Fahrenheit , or less, please contact our office. |
Ambient humidity | 35 to 85 % RH, Storage: 35 to 85 % RH |
Ambient illuminance | Incandescent light: 3,500 Lx or less at the light-receiving face |
Voltage withstandability | 1,500 V AC for one min. between power supply and output terminals 1,000 V AC for one min. between relay contact terminals |
Insulation resistance | 20 MOhm , or more, with 500 V DC megger between power supply and output terminals, and between relay contact terminals |
Vibration resistance | 10 to 55 Hz frequency, 1.5 mm 0.059 in double amplitude in X, Y and Z directions two hours each |
Shock resistance | 500 m/s2 (50 G approx.) in X, Y and Z directions three times each |
Emitting element | Red LED (modulated) |
Emitting element:Peak emission wavelength | 660 nm 0.026 mil |
Material | Enclosure: Polycarbonate Lens: Polycarbonate Cover: Polycarbonate |
Cable | 0.3 mm2 5-core (emitter: 2-core) cabtyre cable, 2 m 6.562 ft long |
Cable extension | Extension up to total 100 m 328.084 ft is possible with 0.3 mm2, or more, cable (both emitter and receiver). |
Weight | Emitter: 100 g approx Receiver: 140 g approx |
Accessory | Adjusting screwdriver: 1 pc. |